Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.5 No.3 pp.251-257
DOI :

서울시 지하철의 소음 노출 실태에 관한 연구

박민수, 표현미, 손종렬, 변상훈*
고려대학교 보건과학대학 환경보건학과

A Study on the Sound Level Exposure at Seoul Metro

Sang-Hoon Byeon*, Min-Soo Park, Hyun-Mi Pyo, Jong-Ryeul Sohn
Department of Environmental Health, College of Health Science, Korea University

Abstract

According to the measurements at Seoul Metro subway, the sound level at the time of subway arrivalranged from 77.0 to 92.5 dB(A). The highest level was 92.5 dB(A) at Line-1, and the lowest level was 77.0dB(A) at Line-5. The sound level of departure ranged from the lowest level of 82.9 dB(A) at Line-5 and thehighest level of 95 dB(A) at Line-1.The indoor sound level at subway ranged from the lowest level of 87.2 dB(A) (Line-6) to the highest valueof 92.1 dB(A) (Line-1).The results of this study also showed that the sound level at subway platform with Platform ScreenDoor(PSD) showed 81.8 dB(A) but 89.1 dB(A) without PSD. The sound reduction effect of PSD showed 7.3dB(A) at platform. Consequently, the sound level in Korean subway was found to exceed the standard setfor the American Public Transportation Association (85dB(A)).

A9RDDD8.pdf450.3KB

Reference